Product Description

Portable Steam Sterilizer sales


Portable steam sterilizer is steam sterilizer equipment that utilizes saturated pressure steam and is suitable for medical and health undertakings,scientific research,and agriculture. Classification of high-pressure steam sterilizers is divided into portable steam sterilizer,vertical pressure steam sterilizers,and horizontal high-pressure steam sterilizers according to the size of the models.
Sterilization and sterilization of medical devices, dressings,glassware, and solution culture media also apply to high-altitude drinking water in highland areas for cooking equipment and enterprises and institutions,as well as high-temperature steam source equipment.
Portable autoclaves are 18L and 24L.Vertical high-pressure steam sterilizers are available from 30L to 100L.Each of the same volume is divided into handwheel type,clamshell type,and intelligent type.Intelligent type is also divided into standard configuration,steam line,and vacuum drying.type.You can also add printers according to your requirements.There is also a large horizontal autoclave.
The principle of autoclaving is:in a closed steamer,the steam cannot overflow, and the pressure rises continuously,so that the boiling point of water is continuously increased,so that the temperature in the pot also increases.At a pressure of 0.1 MPa,the pot temperature reached 121°C.At this steam temperature,various bacteria and their highly heat-resistant principle can be quickly killed.
Note: The air in the pot is completely eliminated,so that the pot is saturated with water vapor,and sterilization is complete.There are several different approaches to autoclave deflation, but the goal is to drain the air so that the pan warms up evenly to ensure complete sterilization.Commonly used method is:close the air release valve,after the power is turned on,when the pressure rises to 0.05 MPa,open the air release valve, release the air,wait until the pressure gauge pointer returns to zero,and then close the air release valve.After closing the valve and reenergizing, when the pressure gauge rises to 0.1 MPa, the timer is started and the pressure is maintained at 0.1 to 0.15 MPa for 20 minutes.
After the pressure holding time is reached,the power supply can be cut off.When the pressure drops to 0.05 MPa,the vapor can be slowly released.Care should be taken not to reduce the pressure too quickly,which leads to intense decompression boiling and overflow of the liquid in the container.When the pressure drops to zero,the lid can only be opened,the medium is removed and placed on the platform for condensation.Do not let go for a long time,cause the composition of the medium to change,so that the medium can not be inclined. Once placed too long, due to the negative pressure inside the boiler,the lid cannot be opened,as long as the air release valve is opened,the atmospheric pressure enters,the pressure inside and outside is balanced, and the cover is easy to open.
Articles that are not destructive after autoclaving,such as sterile water,culture media,and inoculation utensils, can extend sterilization time or increase pressure.The medium should strictly adhere to the pressure holding time,not only to maintain the pressure completely, but also to prevent the composition of the medium deterioration or reduced efficacy,can not arbitrarily extend the time.
1.First remove the inner sterilizing barrel and then add the appropriate amount of water to the outer pot so that the water surface is level with the triangle shelf.
2.Put it back in the sterilizer and load the item to be sterilized.Be careful not to squeeze too much so as not to interfere with steam circulation and affect the sterilization effect.The conical flask and test tube end should not be in contact with the barrel wall,so as to prevent the condensate from soaking the paper in the mouth and penetrating the tampon.
3.Cap and insert the capped exhaust hose into the exhaust compartment of the inner sterile tank.Then tighten the two opposite bolts in two or two symmetrical ways to ensure that the bolts are tight and tight,so that no air leakage occurs.
4.Heat with an electric furnace or gas,and open the exhaust valve at the same time so that the water boils to remove cold air from the pot.After the cold air is completely drained, close the exhaust valve so that the temperature in the pan gradually increases as the steam pressure increases.When the pot pressure rises to the desired pressure,control the heat source and maintain the pressure for the desired time.This experiment was sterilized using 1.05 kg/cm2,121.3°C,for 20 minutes.
5.After the time required for sterilization is reached,cut off the power supply or shut off the gas,so that the temperature in the sterilizing pot naturally drops.When the pressure on the pressure gauge drops to 0,open the exhaust valve,loosen the

Portable steam sterilizer

Looking for ideal Portable Steam Sterilizer Manufacturer & supplier ? We have a wide selection at great prices to help you get creative. All the Portable Steam Sterilizer Sales are quality guaranteed. We are China Origin Factory of Portable Steam Sterilizer Wholesale. If you have any question, please feel free to contact us.