Product Description

Self contained organism Indicator

Self contained organism indicator are a special type of live microbial products that can be used to confirm the performance of sterilization equipment,verification of sterilization procedures,and monitoring of sterilization effects in the production process;the definition of biological indicators is:for specific sterilization treatment Determine the resistance and install the bacterial carriers available for use in the inner packaging.Used to confirm the performance of sterilization equipment,verification of sterilization procedures,monitoring of sterilization effects in production processes,etc.
Self contained organism indicator biological Indicators Category:
1.According to the structure,it can be divided into strip biological indicator and self-contained biological indicator;the sheet biological indicator needs to use positive control and negative control,and self-contained Biological indicators only need a positive control.Sanqiang sterilizer uses self-contained biological indicators for Self contained organism indicator sterilization testing.
2.According to the classification of ISO 11138-1(2006),the current biological indicators are biological indicators for ethylene oxide sterilization,biological indicators for moist heat sterilization,biological indicators for dry heat sterilization,hydrogen peroxide Low-temperature plasma sterilization of biological indicators and biological indicators for the sterilization of formaldehyde.
3.According to the culture time can be divided into general biological indicators and rapid biological indicators.The universal biological indicator changes the pH value of the culture solution according to the metabolism of the indicator strain after the resuscitation of the spores,and the interpretation is performed through the discoloration of the acid-base indicator,and the time is generally at 48 hours;and the rapid biological indicator is based on the enzymatic action after the resuscitation of the spores.The reaction is interpreted by fluorescence and the time is generally 3-4 hours.The Sanqiang brand bioindicator test uses the 48-hour test result.
Self contained organism indicator weight quality characteristics:
1.Spore content
2.D(measurement by survival curve method)
In the verification of the sterilization procedure,although the sterilization effect can be evaluated through the monitoring of certain parameters of the sterilization process,the degree of killing of the biological indicator is the most intuitive indicator for evaluating the effectiveness of a sterilization procedure.Commercially available standard biological indicators can be used, as can spores prepared with the most resistant micro-organisms isolated during daily production monitoring of contaminants.In the biological indicator verification test,the D value of the spore under the actual sterilization condition needs to be determined, and the spore purity and quantity are determined. When verifying,the microbial indicator of the biological indicator should be larger than the routine detection of microbial contamination,and the tolerance is strong to ensure that the sterilization procedure has greater safety.In the final sterilization method,biological indicators should be placed in different parts of the sterilizer.And avoid direct contact with the indicator to be sterilized items.The biological indicators are sterilized after being sterilized according to the set conditions,and cultured in a culture medium respectively to determine whether the spores in the biological indicator are completely killed.Excessive sterilization of product sterilization generally does not consider the level of microbial contamination,commercially available biological indicators.For products with poor resistance to sterilization,when designing sterilization procedures,the level of microbial contamination of the product in the production process is estimated based on experience,and the number of species and spores of the biological indicator is selected.The sterility assurance of this type of product should be evaluated by monitoring the data obtained by verifying the quantity,tolerance and verification of the sterilization process before each batch of sterilized microorganisms.




Self contained organism indicator

Looking for ideal Self Contained Organism Indicator Manufacturer & supplier ? We have a wide selection at great prices to help you get creative. All the Self Contained Organism Indicator Sales are quality guaranteed. We are China Origin Factory of Self Contained Organism Indicator Wholesale. If you have any question, please feel free to contact us.